§ 14.04.510. Sections 4.202 - 4.202.1.1 are added to the 2016 edition of the California Green Building Standards Code to read as follows.
Section 4.202 Renewable Energy. Sections 4.202.1 and 4.202.1.1 shall apply to residential, multifamily, mixed use buildings.
4.202.1 Space fore Future Electrical Solar System Installation [N] Comply with Section 110.10 of the California Energy Code 4.202.1.1 Future access for Electrical Solar System [N]. For new buildings or when an existing service is relocated to new construction area, a minimum of one inch electrical conduit shall be provided from the electrical service equipment to an accessible location of the attic or other location suitable for future connection to a solar system. The conduit shall be labeled as future access for electrical solar system. The electrical panel shall be sized to accommodate the installation of future electrical solar system.
Exception: Buildings not required to provide a solar zone per Section 110.10 of the California Energy Code.
(Ord. No. 7289, § 3(J), 12-12-2016)