§ 14.04.516. Section A4.106.5.3 of the 2016 California Green Building Standards Code is deleted and Tables A4.106.5.1(1) through A4.106.5.1(4) of the 2016 California Green Buildings Standards Code are amended to read as follows.  


Latest version.
  • A4.106.5.3 Solar Reflectance index alternative. Solar Reflectance index (SRI) equal to or greater than the values.

    TABLE A4 106.5.1 (1) TIER 1-LOW RISE RESIDENTIAL
    ROOF SLOPE MINIMUM 3-YEAR AGED
    SOLAR
    REFLECTANCE
    THERMAL
    EMITTANCE
    ≤2:12 0.68 0.85
    >2:12 0.28 0.85

     

    TABLE A4.106.5.1 (2) TIER 2-LOW-RISE RESIDENTIAL
    ROOF SLOPE MINIMUM 3-YEAR AGED
    SOLAR
    REFLECTANCE
    THERMAL
    EMITTANCE
    ≤2:12 0.70 0.85
    >2:12 0.34 0.85

     

    TABLE A4.106.5.1(3) TIER 1 - HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS
    ROOF SLOPE MINIMUM 3-YEAR AGED
    SOLAR
    REFLECTANCE
    THERMAL
    EMITTANCE
    ≤2:12 0.68 0.85
    >2:12 00.28 0.85

     

    TABLE A4.106.5.1(4) TIER 2 - HIGH-RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS
    ROOF SLOPE MINIMUM 3-YEAR AGED
    SOLAR
    REFLECTANCE
    THERMAL
    EMITTANCE
    ≤2:12 0.70 0.85
    >2:12 0.34

     

(Ord. No. 7289, § 3(J), 12-12-2016)