§ 13.24.300. Backwater traps and valves.  


Latest version.
  • In every case where a plumbing outlet or plumbing fixture is installed or located below the elevation of the curb or property line, an approved type of backwater trap or an approved type of backwater sewer valve shall be installed between the outlet and the public sewer in such a manner as to prevent sewage from flowing back or backing up into any such outlet or plumbing fixture. Every such trap or valve shall be installed in the basement, or in a box or manhole of concrete, or cast iron, or other material approved by the superintendent so that it will be readily accessible at all times. The trap or valve shall be placed only in the drain line serving the fixtures that are located below the elevation of the above-mentioned curb or property line and no drainage from fixtures located above this elevation shall pass through such trap or valve.

(Ord. 4170 § 2.12, 1950)